Home / Resources / Article

TEG, MEG and methanol: glycols for gas dehydration and hydrate control

Water in natural gas causes hydrates, corrosion and off-spec gas. Triethylene glycol removes it in dehydration units. Monoethylene glycol and methanol are injected to stop hydrates forming.

Why water matters in gas

Produced gas is usually saturated with water. As it cools under pressure, that water can form hydrates: ice-like solids that block pipelines and equipment. Water also drives corrosion, and sales gas has to meet a water dew point specification.

TEG for dehydration

In a glycol dehydration unit, gas flows up through a contactor while lean triethylene glycol flows down and absorbs the water. The rich glycol is then heated in a reboiler to drive the water off and returned to the contactor.

TEG begins to degrade at reboiler temperatures above about 204 °C (400 °F). Units therefore run below that, and losses from carry-over and degradation are made up with regular top-ups of clean TEG.

MEG for hydrate inhibition

Monoethylene glycol is injected into wells and flowlines to lower the temperature at which hydrates form. In continuous service it is usually recovered and regenerated, so consumption is mainly the losses.

Methanol for hydrate inhibition

Methanol is very effective at preventing and dissolving hydrates, but much of it ends up in the gas and condensate rather than being recovered. That makes it common for intermittent use, start-up and remedial treatment.

Methanol is highly flammable and toxic, so handling and storage need care.

Quality points for glycol supply

  • Purity and water content. Both affect how well the glycol absorbs water.
  • Contamination. Salts, hydrocarbons and chlorides cause foaming, fouling and corrosion in the unit.
  • Clean transfer. Dedicated or properly cleaned transport and containers keep the product on specification.

Amines for sweetening

Where gas contains hydrogen sulphide or carbon dioxide, amine units such as those running monoethanolamine (MEA) remove these acid gases before dehydration.

General guidance only. Always follow your engineering programme, the product safety data sheet and the current edition of any standard referred to.